Diagnostic & Aftercare

Inverter Error Code Lookup

Lookup fault codes, meanings, and recommended action steps for Growatt, Deye, and Huawei solar inverters installed across Myanmar.

31 error codes indexed
Growatt01warning

Fan Locked

Meaning: Inverter fan is locked or not functioning properly.

Recommended Action:

Check if fan is blocked by dust/debris. Restart inverter. If persists, fan replacement needed.

Growatt02critical

Over Temperature

Meaning: Internal inverter temperature exceeds safe limit.

Recommended Action:

Ensure adequate ventilation, clear heat sinks, reduce heavy continuous load during hot hours.

Growatt03warning

Battery Voltage High

Meaning: Battery voltage exceeded maximum operating threshold.

Recommended Action:

Check BMS settings, verify charge controller configuration and battery bank voltage.

Growatt04warning

Battery Voltage Low

Meaning: Battery discharged below cut-off threshold.

Recommended Action:

Allow solar or grid recharge. If battery does not recover, inspect battery health/cells.

Growatt05critical

Output Short Circuit

Meaning: Short circuit detected on AC output / load side.

Recommended Action:

Turn off AC breaker. Check wiring and disconnected loads one by one to isolate the faulty appliance.

Growatt06critical

Output Voltage High

Meaning: Output voltage above permissible inverter regulation range.

Recommended Action:

Disconnect load, restart inverter. If error returns without load, internal power stage failure.

Growatt07warning

Overload Timeout

Meaning: Inverter ran in overload state longer than allowed duration.

Recommended Action:

Reduce appliance load. Match continuous appliance wattage to inverter rating.

Growatt08critical

Bus Voltage High

Meaning: DC Bus voltage exceeded safe operating limit.

Recommended Action:

Check PV array open-circuit voltage (Voc) under cold weather; verify it does not exceed max MPPT limit.

Growatt09critical

Bus Soft Start Failed

Meaning: Inverter failed to charge internal DC bus capacitors during startup.

Recommended Action:

Restart system. If fault persists, internal circuitry issue requiring repair.

Growatt51critical

Over Current Fault

Meaning: Inverter hardware overcurrent detected.

Recommended Action:

Check for motor/compressor surge spikes. Restart and test with lower surge loads.

Growatt52warning

Bus Voltage Low

Meaning: DC bus voltage dropped below operational limit during power delivery.

Recommended Action:

Check battery discharge rate and PV input stability during high load steps.

Growatt58warning

Output Voltage Low

Meaning: AC output voltage dropped below threshold under load.

Recommended Action:

Reduce connected load. Inspect AC output terminal connections.

DeyeF01critical

DC Bus Precharge Fault

Meaning: DC bus failed pre-charging before grid connection.

Recommended Action:

Inspect DC wiring, battery connection, and restart inverter switch.

DeyeF08critical

GFCI / Ground Fault

Meaning: Ground fault current or leakage current too high.

Recommended Action:

Check PV cable insulation, solar panel frames grounding, and moisture in junction boxes.

DeyeF13warning

Grid Over Frequency

Meaning: Utility grid / generator frequency higher than standard parameter.

Recommended Action:

Check generator governor or grid parameter settings in inverter setup.

DeyeF14warning

Grid Under Frequency

Meaning: Grid or generator frequency dropped below operating window.

Recommended Action:

Verify generator output frequency and stability under heavy load.

DeyeF18critical

AC Overcurrent Fault

Meaning: Hardware AC overcurrent protection triggered.

Recommended Action:

Check for heavy motor starts or short circuits on backup AC output ports.

DeyeF20critical

DC Overcurrent Fault

Meaning: Excessive DC current on PV or battery input.

Recommended Action:

Verify PV string configuration and battery charge/discharge current limits.

DeyeF23critical

Insulation Resistance Low

Meaning: PV array insulation resistance to ground is below threshold (ISO fault).

Recommended Action:

Inspect PV DC wiring for damaged jacket, conduit water ingress, or pinched solar wires.

DeyeF26critical

Bus Overvoltage

Meaning: Internal DC bus voltage exceeded limit.

Recommended Action:

Verify PV string Voc under cold ambient temperatures does not exceed inverter maximum.

DeyeF29warning

Heatsink Over Temperature

Meaning: Internal power module heatsink temperature too high.

Recommended Action:

Clean air filters and heatsink fins. Verify installation clearance requirements.

DeyeF42warning

Grid Over Voltage

Meaning: Grid voltage is higher than acceptable range.

Recommended Action:

Measure grid voltage with multimeter; adjust local grid code overvoltage settings if permitted.

DeyeF56warning

Battery Voltage Low

Meaning: Battery voltage too low for normal operation.

Recommended Action:

Recharge battery bank. Check battery breaker and cable connections.

DeyeF58warning

BMS Communication Lost

Meaning: Communication between inverter and lithium battery BMS interrupted.

Recommended Action:

Check RS485 / CAN communication cable, baud rate, and lithium battery protocol settings.

Huawei2001critical

High String Voltage

Meaning: PV array open-circuit voltage is higher than the max inverter input voltage.

Recommended Action:

Immediately disconnect PV switch. Recalculate string length and remove excess panels per string.

Huawei2002critical

DC Arc Fault (AFCI)

Meaning: DC arc detected in PV string wiring.

Recommended Action:

Check PV connectors (MC4), crimps, and junction boxes along the string for loose contacts or damage.

Huawei2031warning

Grid Overvoltage

Meaning: Grid voltage higher than safety limit or grid disconnected.

Recommended Action:

Check AC breaker. If grid is present, check AC voltage level and grid standard settings.

Huawei2032info

Grid Undervoltage

Meaning: Grid voltage lower than safety limit (outage or brownout).

Recommended Action:

Normal during power outages in Myanmar. Inverter switches to island/backup mode if configured.

Huawei2062critical

Low Insulation Resistance

Meaning: Short circuit between PV string and ground.

Recommended Action:

Inspect DC lines for ground leakage, degraded cable insulation, or water in rooftop conduits.

Huawei2064warning

Heatsink Over Temperature

Meaning: Internal components exceeded operational temperature.

Recommended Action:

Ensure inverter is installed away from direct afternoon sunlight; clean cooling fins.

Huawei61440critical

Internal Fault

Meaning: Inverter self-test failed or internal hardware fault.

Recommended Action:

Power cycle both AC and DC isolators for 5 minutes. If persists, contact certified service support.